Luminometer
  4 Benchtop Luminometer
4 Portable Luminometer
4 MiniT Incubator
   

 

QuantiDNA® and QuantiVirus® Benchtop Luminometer

  • Affordable 96 well Plate Based Luminometer-affordable luminometer with exceptional sensitivity and high precision.
  • Validated for QuantiVirus Assays- The Diacarta Luminometer has been validated for QuantiVirus assays.
  • Validated for QuantiDNA Assays- The Diacarta Luminometer has been validated for QuantiDNA Assays.
  • User friendly Software- Simple wizard driven software allows for easy experimental set-up.
  • Data Analysis- Use the built in analysis functions or simply export to excel for off line data reduction.

Specifications

Wavelength range:

300 to 700nm with peak at 480 nm

Power Supply:    

110-250V, 50/60HZ, 240VA

Storage Temperature:

0oC to 40oC

Operation Range:

15oC to 40oC

Humidity:

10% to 85%

Detector Unit:

Low-noise Photo multiplier tube

Sensitivity:

<20 amol ATP

Dynamic Range:

>6 orders of Magnitude

Crosstalk:

Low crosstalk design: 10-6

Plate:

96 microplate

Software:

Build-in microprocessor, storage of different measuring protocols

Interface:

RS232 C interface for data transfer to a PC

Measurement Integral:

0.2 to 1 Sec.

Linearity range:

10 – 5000000 RLU

Data Storage:

Storage of the last results

PC-software:

Data capture software program for easy data transfer and evaluation

Port:

RS232 serial port or USB port

Dimension:

644mmX440mmX278mm

Weight:

15Kg

Repeatability:

CV<2%

 

 

QuantiDNA® and QuantiVirus® Portable Luminometer

 

Specifications

Wavelength range:

300 to 700nm

Power Supply:   

110-230V, 50/60HZ, 240VA

Battery, 8 hrs support, rechargeable

Storage Temperature:

0oC to 40oC

Operation Range:

15oC to 40oC

Humidity:

10% to 85%

Dimensions:

280 X 180 X 150mm3 

Weight: 

< 2KG

Detector Unit:

Low-noise Photo multiplier tube

Sensitivity:

<20 amol ATP

Dynamic Range:

>6 orders of Magnitude

Crosstalk:

Low crosstalk design: 10-6

Display:

Graphic display

Software:

Build-in microprocessor, storage of different measuring protocols

Interface:

RS232 C interface for data transfer to a PC

Measurement Integral:

0.2 to 1 Sec.

Data Storage:

Storage of the last results

PC-software:

Data capture software program for easy data transfer and evaluation

Batteries:

Rechargeable batteries

Repeatability:

CV<2%

 

 

 

 

 

 

 

 

 

 

 

QuantiDNA® and QuantiVirus® MiniT Incubator

Model :

MiniT

Power supply :

DC 12V

Power :

10 W

Temperature range :

RT+5℃ ~ 60℃

Timing range :

1sec~99h 59min 59sec

Accuracy of the temperature :

<=±0.5℃

Display accuracy :

 0.1℃

Heating time(from 20℃ to 60℃ ) :

 <=5min

Ambient temperature :

5℃~35℃

Dimensions(W x D x H) :

114mm X 150mmX 60mm

Weight :

0.5㎏


     

© DiaCarta 2003 - 2008. All rights reserved